✨ New Arrivals Just Dropped!Explore
Boston Scientific M00555540 Acquire EUS FNB Needle - 22 Gauge, Franseen Tip
HomeStore

Boston Scientific M00555540 Acquire EUS FNB Needle - 22 Gauge, Franseen Tip

Boston Scientific M00555540 Acquire EUS FNB Needle - 22 Gauge, Franseen Tip

$103.95

Original: $297.00

-65%
Boston Scientific M00555540 Acquire EUS FNB Needle - 22 Gauge, Franseen Tip

$297.00

$103.95

The Story

Boston Scientific Acquire™ EUS-FNB | 22G | M00555540

The Boston Scientific Acquire™ (M00555540) is widely regarded as the clinical "workhorse" for Endoscopic Ultrasound-guided Fine Needle Biopsy (EUS-FNB). While cytology needles often return fragmented cells, the 22G Acquire™ is specifically engineered to harvest large, intact histological cores.

By utilizing a proprietary Franseen tip, this device preserves the underlying tissue architecture, providing the essential "tissue-of-origin" data required for precise tumor grading, lymphoma sub-typing, and the high-volume material demands of 2026 molecular profiling.

Key Performance Features

  • Franseen "Crown" Tip Geometry: Features a three-point symmetrical cutting edge. This design slices cleanly through dense or fibrotic lesions (common in pancreatic pathology), capturing a core that reflects the true histological state of the target tissue.

  • Cobalt Chromium (CoCr) Alloy: The 22G needle is forged from CoCr, which provides superior hardness and kink resistance compared to standard stainless steel. This ensures the needle maintains its "memory" and sharpness throughout multiple passes in high-resistance lesions.

  • Maximized Diagnostic Yield: The 22G diameter is optimized to provide a substantial tissue volume, reducing the number of passes required to achieve an adequate sample and potentially lowering procedural time.

  • Advanced Echogenicity: The needle tip is engineered for high visibility under ultrasound. This clear echogenic signature allows for precise "fanning" maneuvers while maintaining absolute needle-tip visualization.

  • Customizable Reach: Features a needle extension range of 0 to 8 cm and an adjustable working length, allowing for safe and accurate access to perigastric, periduodenal, and mediastinal targets.

Technical Specifications

  • Manufacturer: Boston Scientific

  • Product Code: M00555540

  • Needle Gauge: 22G

  • Tip Design: Franseen (3-point cutting)

  • Material: Cobalt Chromium (CoCr)

  • Working Length: Adjustable 137.5 cm – 141.5 cm

  • Needle Extension: 0–8 cm

  • Minimum Working Channel: 2.4 mm

Clinical & Institutional Advantages

  • Molecular Testing Efficiency: Provides the significant tissue volume required for Immunohistochemistry (IHC), Fluorescence In Situ Hybridization (FISH), and Next-Generation Sequencing (NGS).

  • Enhanced Pathological Accuracy: Core samples allow for the assessment of tissue stroma and spatial architecture, which is often lost in traditional Fine Needle Aspiration (FNA).

  • Strategic Value: Acquiring genuine Boston Scientific overstock allows facilities to maintain the highest standard of FNB technology while optimizing procedural budgets for high-volume GI suites.

Ideal Applications

  • Pancreatic Head & Body Masses: Primary diagnosis of solid lesions.

  • Mediastinal & Abdominal Lymphadenopathy: Nodal staging for gastric and esophageal malignancies.

  • Subepithelial Tumors: Definitive biopsy for GIST and leiomyomas.

Condition & Quality Assurance

  • Status: NEW — Genuine Boston Scientific Overstock.

  • Packaging: Original OEM sterile tray packaging. The factory Tyvek seal is 100% intact.

  • Kit Contents: (1) 22G FNB Needle, (1) 20cc Vacuum Syringe, and (1) One-way Stopcock.

Boston Scientific M00555540 Acquire EUS FNB Needle - 22 Gauge, Franseen Tip - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

Boston Scientific Acquire™ EUS-FNB | 22G | M00555540

The Boston Scientific Acquire™ (M00555540) is widely regarded as the clinical "workhorse" for Endoscopic Ultrasound-guided Fine Needle Biopsy (EUS-FNB). While cytology needles often return fragmented cells, the 22G Acquire™ is specifically engineered to harvest large, intact histological cores.

By utilizing a proprietary Franseen tip, this device preserves the underlying tissue architecture, providing the essential "tissue-of-origin" data required for precise tumor grading, lymphoma sub-typing, and the high-volume material demands of 2026 molecular profiling.

Key Performance Features

  • Franseen "Crown" Tip Geometry: Features a three-point symmetrical cutting edge. This design slices cleanly through dense or fibrotic lesions (common in pancreatic pathology), capturing a core that reflects the true histological state of the target tissue.

  • Cobalt Chromium (CoCr) Alloy: The 22G needle is forged from CoCr, which provides superior hardness and kink resistance compared to standard stainless steel. This ensures the needle maintains its "memory" and sharpness throughout multiple passes in high-resistance lesions.

  • Maximized Diagnostic Yield: The 22G diameter is optimized to provide a substantial tissue volume, reducing the number of passes required to achieve an adequate sample and potentially lowering procedural time.

  • Advanced Echogenicity: The needle tip is engineered for high visibility under ultrasound. This clear echogenic signature allows for precise "fanning" maneuvers while maintaining absolute needle-tip visualization.

  • Customizable Reach: Features a needle extension range of 0 to 8 cm and an adjustable working length, allowing for safe and accurate access to perigastric, periduodenal, and mediastinal targets.

Technical Specifications

  • Manufacturer: Boston Scientific

  • Product Code: M00555540

  • Needle Gauge: 22G

  • Tip Design: Franseen (3-point cutting)

  • Material: Cobalt Chromium (CoCr)

  • Working Length: Adjustable 137.5 cm – 141.5 cm

  • Needle Extension: 0–8 cm

  • Minimum Working Channel: 2.4 mm

Clinical & Institutional Advantages

  • Molecular Testing Efficiency: Provides the significant tissue volume required for Immunohistochemistry (IHC), Fluorescence In Situ Hybridization (FISH), and Next-Generation Sequencing (NGS).

  • Enhanced Pathological Accuracy: Core samples allow for the assessment of tissue stroma and spatial architecture, which is often lost in traditional Fine Needle Aspiration (FNA).

  • Strategic Value: Acquiring genuine Boston Scientific overstock allows facilities to maintain the highest standard of FNB technology while optimizing procedural budgets for high-volume GI suites.

Ideal Applications

  • Pancreatic Head & Body Masses: Primary diagnosis of solid lesions.

  • Mediastinal & Abdominal Lymphadenopathy: Nodal staging for gastric and esophageal malignancies.

  • Subepithelial Tumors: Definitive biopsy for GIST and leiomyomas.

Condition & Quality Assurance

  • Status: NEW — Genuine Boston Scientific Overstock.

  • Packaging: Original OEM sterile tray packaging. The factory Tyvek seal is 100% intact.

  • Kit Contents: (1) 22G FNB Needle, (1) 20cc Vacuum Syringe, and (1) One-way Stopcock.

Boston Scientific M00555540 Acquire EUS FNB Needle - 22 Gauge, Franseen Tip | Primis Medical