Original: $100.00
-65%$100.00
$35.00The Story
Ethicon J495H 5-0 Coated VICRYL Undyed Suture | PS-2 19mm Prime Reverse Cutting | Box of 36
The Ethicon J495H is a high-precision Coated VICRYL® (Polyglactin 910) synthetic absorbable suture, meticulously engineered for delicate soft tissue approximation where aesthetic results are the primary goal. This Size 5-0 undyed braided suture is a clinical gold standard for subcuticular skin closures and facial reconstruction, offering a natural, low-visibility profile that won't "show through" thin dermal layers. Paired with the elite PS-2 (Plastic Surgery) needle, the J495H provides exceptional control and reduced penetration force, ensuring exact wound edge alignment in the most sensitive anatomical areas.
The PS-2 needle is a 19mm, 3/8 circle Prime™ Reverse Cutting needle. Crafted from high-strength surgical alloy, this MultiPass™ needle is designed to maintain its superior sharpness through multiple passes, significantly reducing tissue trauma and post-operative inflammatory responses.
Key Specifications
-
Manufacturer: Ethicon (Johnson & Johnson)
-
Brand: Coated VICRYL®
-
Model/Part Number: J495H
-
Suture Size: 5-0 (USP)
-
Length: 18 Inches (45 cm)
-
Material: Coated Braided Polyglactin 910
-
Color: Undyed (Natural/White) for a "disappearing" subsurface look
-
Needle Name: PS-2 Prime™
-
Needle Type: 19mm, 3/8 Circle, Reverse Cutting
-
Specialty: MultiPass™ Technology & Precision Cosmetic Geometry
-
Quantity: High-Capacity Box of 36 Individual Sterile Packets
Technical & Professional Advantages
-
Prime™ Needle Sharpness: The PS-2 needle features a specialized geometry that requires significantly less penetration force than standard cutting needles, allowing for effortless passage through tough dermis without "bunching" the tissue.
-
MultiPass™ Durability: Engineered to remain sharp pass after pass, the MultiPass™ technology ensures consistent performance throughout the entire closure, making it ideal for intricate, multi-layer interrupted suturing.
-
Superior Tensile Strength: Despite its fine 5-0 diameter, it provides reliable mechanical support during the critical early healing window, retaining approximately 75% of its strength at 14 days and 50% at 21 days.
-
Exceptional Braided Handling: The proprietary coating ensures a smooth "zip" through tissues with minimal drag, while the braided structure provides the superior knot security required for tension-free cosmetic closures.
-
Predictable Absorption: Undergoes complete absorption via hydrolysis within 56 to 70 days, allowing the suture to vanish once the tissue has successfully regained its natural structural integrity.
Condition & Quality Assurance
-
Status: New – Brand New in Original Factory Packaging.
-
Integrity: Both the internal sterile foil barriers and the outer manufacturer's box are fully intact and factory-sealed, ensuring the chemical and structural integrity of the Polyglactin 910.
-
Storage & Handling: Primis Medical manages all sterile inventory in a temperature-controlled environment, strictly adhering to AAMI and OEM standards.
-
Expertise: Our staff has over 25 years of experience in Hospital Materials, ensuring your precision sutures are authentic, unexpired, and ready for the operating room.
Shipping
-
Fast Dispatch: Ships within 1 business day.
-
Secure Logistics: Suture boxes are carefully packaged to protect the delicate 19mm PS-2 needles and sterile foil seals from environmental stressors during transit.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
Ethicon J495H 5-0 Coated VICRYL Undyed Suture | PS-2 19mm Prime Reverse Cutting | Box of 36
The Ethicon J495H is a high-precision Coated VICRYL® (Polyglactin 910) synthetic absorbable suture, meticulously engineered for delicate soft tissue approximation where aesthetic results are the primary goal. This Size 5-0 undyed braided suture is a clinical gold standard for subcuticular skin closures and facial reconstruction, offering a natural, low-visibility profile that won't "show through" thin dermal layers. Paired with the elite PS-2 (Plastic Surgery) needle, the J495H provides exceptional control and reduced penetration force, ensuring exact wound edge alignment in the most sensitive anatomical areas.
The PS-2 needle is a 19mm, 3/8 circle Prime™ Reverse Cutting needle. Crafted from high-strength surgical alloy, this MultiPass™ needle is designed to maintain its superior sharpness through multiple passes, significantly reducing tissue trauma and post-operative inflammatory responses.
Key Specifications
-
Manufacturer: Ethicon (Johnson & Johnson)
-
Brand: Coated VICRYL®
-
Model/Part Number: J495H
-
Suture Size: 5-0 (USP)
-
Length: 18 Inches (45 cm)
-
Material: Coated Braided Polyglactin 910
-
Color: Undyed (Natural/White) for a "disappearing" subsurface look
-
Needle Name: PS-2 Prime™
-
Needle Type: 19mm, 3/8 Circle, Reverse Cutting
-
Specialty: MultiPass™ Technology & Precision Cosmetic Geometry
-
Quantity: High-Capacity Box of 36 Individual Sterile Packets
Technical & Professional Advantages
-
Prime™ Needle Sharpness: The PS-2 needle features a specialized geometry that requires significantly less penetration force than standard cutting needles, allowing for effortless passage through tough dermis without "bunching" the tissue.
-
MultiPass™ Durability: Engineered to remain sharp pass after pass, the MultiPass™ technology ensures consistent performance throughout the entire closure, making it ideal for intricate, multi-layer interrupted suturing.
-
Superior Tensile Strength: Despite its fine 5-0 diameter, it provides reliable mechanical support during the critical early healing window, retaining approximately 75% of its strength at 14 days and 50% at 21 days.
-
Exceptional Braided Handling: The proprietary coating ensures a smooth "zip" through tissues with minimal drag, while the braided structure provides the superior knot security required for tension-free cosmetic closures.
-
Predictable Absorption: Undergoes complete absorption via hydrolysis within 56 to 70 days, allowing the suture to vanish once the tissue has successfully regained its natural structural integrity.
Condition & Quality Assurance
-
Status: New – Brand New in Original Factory Packaging.
-
Integrity: Both the internal sterile foil barriers and the outer manufacturer's box are fully intact and factory-sealed, ensuring the chemical and structural integrity of the Polyglactin 910.
-
Storage & Handling: Primis Medical manages all sterile inventory in a temperature-controlled environment, strictly adhering to AAMI and OEM standards.
-
Expertise: Our staff has over 25 years of experience in Hospital Materials, ensuring your precision sutures are authentic, unexpired, and ready for the operating room.
Shipping
-
Fast Dispatch: Ships within 1 business day.
-
Secure Logistics: Suture boxes are carefully packaged to protect the delicate 19mm PS-2 needles and sterile foil seals from environmental stressors during transit.









