✨ New Arrivals Just Dropped!Explore
Synthes 214.564 4.5mm Cannulated Screw Partially Threaded/64mm
HomeStore

Synthes 214.564 4.5mm Cannulated Screw Partially Threaded/64mm

Synthes 214.564 4.5mm Cannulated Screw Partially Threaded/64mm

$14.17

Original: $40.50

-65%
Synthes 214.564 4.5mm Cannulated Screw Partially Threaded/64mm

$40.50

$14.17

The Story

Synthes 4.5mm Cannulated Screw | Partially Threaded | 64mm | 214.564

The Synthes 214.564 is a high-precision internal fixation implant engineered for stable anchorage and active interfragmentary compression in cancellous and metaphyseal bone. As a 4.5mm diameter screw with a 64mm length and a partial thread, it is a foundational component of the Synthes 4.5mm Cannulated Screw System.

The partially threaded design is specifically engineered to function as a "lag screw." Because the threads only engage the far (distal) bone fragment while the smooth proximal shaft glides through the near fragment, the screw head draws the two pieces together upon final tightening. This results in high-tension compression across the fracture line, which is essential for primary bone healing and achieving rotational stability.

Key Specifications

  • Manufacturer: Synthes (DePuy Synthes)

  • Model / REF: 214.564

  • Material: 316L Surgical Stainless Steel

  • Diameter: 4.5 mm

  • Overall Length: 64 mm

  • Thread Type: Partially Threaded (Lag Design)

  • Cannulation: 1.75 mm (Compatible with 1.6mm Guide Wires)

  • Drive Type: 3.5 mm Large Hexagonal Socket

  • Features: Self-Drilling, Self-Tapping, Cannulated

  • Quantity: 1 Each

Technical & Clinical Advantages

  • Precision Guided Placement: The 1.75mm internal bore allows the screw to be delivered over a pre-placed 1.6mm guide wire. This enables the surgeon to confirm the trajectory via fluoroscopy before the screw is seated, facilitating minimally invasive percutaneous placement and reducing soft-tissue disruption.

  • Controlled Interfragmentary Compression: The smooth proximal shaft prevents "thread-locking" in the near fragment. This ensures that the rotational force of insertion is converted entirely into compressive force at the fracture site, promoting rapid biological union.

  • Self-Drilling & Self-Tapping Tip: The distal tip features precision-machined cutting flutes that eliminate the need for separate drilling and tapping steps in most cancellous bone applications. This reduces operative time and minimizes instrumentation requirements on the surgical field.

  • High-Torque Drive Interface: The 3.5mm hexagonal socket provides a robust interface for high-torque insertion into dense bone, minimizing the risk of head stripping during final seating.

  • 316L Stainless Steel Biocompatibility: Forged from vacuum-melted surgical steel, the 214.564 is highly corrosion-resistant and biologically inert, ensuring mechanical reliability during long-term internal fixation.

Applications

  • Ankle & Foot Surgery: Fixation of malleolar fractures, calcaneal osteotomies, and midfoot fusions.

  • Trauma Reconstruction: Stabilization of metaphyseal fragments in the proximal or distal tibia.

  • Pelvic & Acetabular Surgery: Providing stable anchorage in pelvic ring disruptions where 64mm provides the necessary reach for cortical purchase.

  • Pediatric Orthopedics: Precise fixation of epiphyseal fractures (Salter-Harris) where the guide wire protects the growth plate during planning.

Condition & Quality Assurance

  • Status: NEW — Factory Sealed.

  • Integrity: The implant is securely housed within its original manufacturer's packaging. Both inner and outer seals are intact, ensuring full material integrity and suitability for medical use.

  • Sterilization Note: This device is provided in STERILE packaging. It is ready for immediate surgical use, provided the sterile barrier is uncompromised and the expiration date is verified per hospital protocol.

  • Professional Standards: With over 25 years of experience in orthopedic logistics, Primis Medical ensures all Synthes implants are handled and stored to maintain their mechanical and chemical precision.

Shipping & Handling

  • Secure Logistics: Shipped in protective packaging to ensure the precision-machined 64mm shaft remains perfectly straight and the internal cannulation remains unobstructed.

  • Fast Dispatch: Ships within 1 business day.

Synthes

Synthes 214.564 4.5mm Cannulated Screw Partially Threaded/64mm - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Synthes 214.564 4.5mm Cannulated Screw Partially Threaded/64mm - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

Synthes 4.5mm Cannulated Screw | Partially Threaded | 64mm | 214.564

The Synthes 214.564 is a high-precision internal fixation implant engineered for stable anchorage and active interfragmentary compression in cancellous and metaphyseal bone. As a 4.5mm diameter screw with a 64mm length and a partial thread, it is a foundational component of the Synthes 4.5mm Cannulated Screw System.

The partially threaded design is specifically engineered to function as a "lag screw." Because the threads only engage the far (distal) bone fragment while the smooth proximal shaft glides through the near fragment, the screw head draws the two pieces together upon final tightening. This results in high-tension compression across the fracture line, which is essential for primary bone healing and achieving rotational stability.

Key Specifications

  • Manufacturer: Synthes (DePuy Synthes)

  • Model / REF: 214.564

  • Material: 316L Surgical Stainless Steel

  • Diameter: 4.5 mm

  • Overall Length: 64 mm

  • Thread Type: Partially Threaded (Lag Design)

  • Cannulation: 1.75 mm (Compatible with 1.6mm Guide Wires)

  • Drive Type: 3.5 mm Large Hexagonal Socket

  • Features: Self-Drilling, Self-Tapping, Cannulated

  • Quantity: 1 Each

Technical & Clinical Advantages

  • Precision Guided Placement: The 1.75mm internal bore allows the screw to be delivered over a pre-placed 1.6mm guide wire. This enables the surgeon to confirm the trajectory via fluoroscopy before the screw is seated, facilitating minimally invasive percutaneous placement and reducing soft-tissue disruption.

  • Controlled Interfragmentary Compression: The smooth proximal shaft prevents "thread-locking" in the near fragment. This ensures that the rotational force of insertion is converted entirely into compressive force at the fracture site, promoting rapid biological union.

  • Self-Drilling & Self-Tapping Tip: The distal tip features precision-machined cutting flutes that eliminate the need for separate drilling and tapping steps in most cancellous bone applications. This reduces operative time and minimizes instrumentation requirements on the surgical field.

  • High-Torque Drive Interface: The 3.5mm hexagonal socket provides a robust interface for high-torque insertion into dense bone, minimizing the risk of head stripping during final seating.

  • 316L Stainless Steel Biocompatibility: Forged from vacuum-melted surgical steel, the 214.564 is highly corrosion-resistant and biologically inert, ensuring mechanical reliability during long-term internal fixation.

Applications

  • Ankle & Foot Surgery: Fixation of malleolar fractures, calcaneal osteotomies, and midfoot fusions.

  • Trauma Reconstruction: Stabilization of metaphyseal fragments in the proximal or distal tibia.

  • Pelvic & Acetabular Surgery: Providing stable anchorage in pelvic ring disruptions where 64mm provides the necessary reach for cortical purchase.

  • Pediatric Orthopedics: Precise fixation of epiphyseal fractures (Salter-Harris) where the guide wire protects the growth plate during planning.

Condition & Quality Assurance

  • Status: NEW — Factory Sealed.

  • Integrity: The implant is securely housed within its original manufacturer's packaging. Both inner and outer seals are intact, ensuring full material integrity and suitability for medical use.

  • Sterilization Note: This device is provided in STERILE packaging. It is ready for immediate surgical use, provided the sterile barrier is uncompromised and the expiration date is verified per hospital protocol.

  • Professional Standards: With over 25 years of experience in orthopedic logistics, Primis Medical ensures all Synthes implants are handled and stored to maintain their mechanical and chemical precision.

Shipping & Handling

  • Secure Logistics: Shipped in protective packaging to ensure the precision-machined 64mm shaft remains perfectly straight and the internal cannulation remains unobstructed.

  • Fast Dispatch: Ships within 1 business day.

Synthes

Synthes 214.564 4.5mm Cannulated Screw Partially Threaded/64mm | Primis Medical