
Original: $11.00
-65%$11.00
$3.85The Story
Synthes 6.5mm Cannulated Screw | 32mm Thread | 85mm Length | 208.439
The Synthes 208.439 is a high-performance internal fixation implant designed for the stabilization of large bone fractures. As a 6.5mm diameter cannulated screw, it features a hollow central core that allows for precise insertion over a pre-positioned 2.8mm guide wire. This system is the clinical standard for "percutaneous" or minimally invasive techniques, enabling the surgeon to achieve perfect anatomical alignment via fluoroscopy before the screw is advanced.
The 32mm Long Thread configuration (partially threaded) is engineered to provide a powerful lag effect. By ensuring the threads engage the distal fragment while the smooth proximal shaft sits in the near fragment, the screw head draws the bone pieces together, generating high-pressure interfragmentary compression.
Key Specifications
-
Manufacturer: Synthes (DePuy Synthes)
-
Model / REF: 208.439
-
Material: 316L Stainless Steel (Surgical Grade)
-
Screw Diameter: 6.5 mm
-
Thread Profile: 32 mm Partial Thread (Long Thread)
-
Screw Length: 85 mm
-
Cannulation: Compatible with 2.8 mm Guide Wires
-
Head Type: 4.0 mm Hexagonal Socket
-
Quantity: Individually Packaged, Sterile
Technical & Clinical Advantages
-
Guide-Wire Precision: The cannulated design allows for "over-the-wire" insertion. Once the guide wire trajectory is verified, the screw follows the wire exactly, eliminating the risk of "wandering" in dense cancellous bone.
-
Superior Lag Compression: With a 32mm thread length, this screw is optimized for larger fragments. It provides a massive "grip" in the distal bone, allowing the screw head to act as a mechanical vice to close the fracture gap.
-
Self-Drilling & Self-Tapping Tip: The distal tip features high-efficiency cutting flutes that allow the screw to be inserted directly over the guide wire in most cancellous bone applications, reducing operative steps and anesthesia time.
-
High-Torque Hex Drive: The 4.0mm hexagonal recess is designed to transmit the high levels of torque required to seat an 85mm screw into the femoral neck or pelvic cortex without stripping the head.
-
316L Stainless Steel Biocompatibility: Forged for high fatigue resistance, the material is designed to withstand the significant cyclic loads associated with weight-bearing in the femur and tibia during the healing process.
Applications
-
Hip Surgery: Fixation of femoral neck fractures (intracapsular) and slipped capital femoral epiphysis (SCFE).
-
Pelvic & Acetabular Trauma: Stabilization of sacroiliac (SI) joint disruptions and large pelvic ring fractures.
-
Knee Trauma: Compression of large tibial plateau fractures or distal femoral condyle fractures where a long reach (85mm) is required.
-
Arthrodesis: Large-joint fusions requiring significant compressive force across the joint space.
Condition & Quality Assurance
-
Status: NEW — Factory Sealed & Sterile.
-
Integrity: This implant is securely packaged within its original manufacturer's sterile peel-pouch. The packaging is intact, ensuring the product's sterility, material integrity, and full lot traceability for clinical implantation in 2026.
-
Professional Standards: With over 25 years of experience in surgical hardware, Primis Medical ensures all large-fragment implants are stored in climate-controlled environments to preserve the mechanical and sterile integrity of the system.
Shipping & Handling
-
Secure Logistics: Shipped in reinforced packaging to ensure the sterile barrier is protected and the internal cannulation remains unobstructed.
-
Fast Dispatch: Ships within 1 business day.


Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
Synthes 6.5mm Cannulated Screw | 32mm Thread | 85mm Length | 208.439
The Synthes 208.439 is a high-performance internal fixation implant designed for the stabilization of large bone fractures. As a 6.5mm diameter cannulated screw, it features a hollow central core that allows for precise insertion over a pre-positioned 2.8mm guide wire. This system is the clinical standard for "percutaneous" or minimally invasive techniques, enabling the surgeon to achieve perfect anatomical alignment via fluoroscopy before the screw is advanced.
The 32mm Long Thread configuration (partially threaded) is engineered to provide a powerful lag effect. By ensuring the threads engage the distal fragment while the smooth proximal shaft sits in the near fragment, the screw head draws the bone pieces together, generating high-pressure interfragmentary compression.
Key Specifications
-
Manufacturer: Synthes (DePuy Synthes)
-
Model / REF: 208.439
-
Material: 316L Stainless Steel (Surgical Grade)
-
Screw Diameter: 6.5 mm
-
Thread Profile: 32 mm Partial Thread (Long Thread)
-
Screw Length: 85 mm
-
Cannulation: Compatible with 2.8 mm Guide Wires
-
Head Type: 4.0 mm Hexagonal Socket
-
Quantity: Individually Packaged, Sterile
Technical & Clinical Advantages
-
Guide-Wire Precision: The cannulated design allows for "over-the-wire" insertion. Once the guide wire trajectory is verified, the screw follows the wire exactly, eliminating the risk of "wandering" in dense cancellous bone.
-
Superior Lag Compression: With a 32mm thread length, this screw is optimized for larger fragments. It provides a massive "grip" in the distal bone, allowing the screw head to act as a mechanical vice to close the fracture gap.
-
Self-Drilling & Self-Tapping Tip: The distal tip features high-efficiency cutting flutes that allow the screw to be inserted directly over the guide wire in most cancellous bone applications, reducing operative steps and anesthesia time.
-
High-Torque Hex Drive: The 4.0mm hexagonal recess is designed to transmit the high levels of torque required to seat an 85mm screw into the femoral neck or pelvic cortex without stripping the head.
-
316L Stainless Steel Biocompatibility: Forged for high fatigue resistance, the material is designed to withstand the significant cyclic loads associated with weight-bearing in the femur and tibia during the healing process.
Applications
-
Hip Surgery: Fixation of femoral neck fractures (intracapsular) and slipped capital femoral epiphysis (SCFE).
-
Pelvic & Acetabular Trauma: Stabilization of sacroiliac (SI) joint disruptions and large pelvic ring fractures.
-
Knee Trauma: Compression of large tibial plateau fractures or distal femoral condyle fractures where a long reach (85mm) is required.
-
Arthrodesis: Large-joint fusions requiring significant compressive force across the joint space.
Condition & Quality Assurance
-
Status: NEW — Factory Sealed & Sterile.
-
Integrity: This implant is securely packaged within its original manufacturer's sterile peel-pouch. The packaging is intact, ensuring the product's sterility, material integrity, and full lot traceability for clinical implantation in 2026.
-
Professional Standards: With over 25 years of experience in surgical hardware, Primis Medical ensures all large-fragment implants are stored in climate-controlled environments to preserve the mechanical and sterile integrity of the system.
Shipping & Handling
-
Secure Logistics: Shipped in reinforced packaging to ensure the sterile barrier is protected and the internal cannulation remains unobstructed.
-
Fast Dispatch: Ships within 1 business day.













